Dometic RV fridges (RM3762 and RM3962) Where the code shows: On the control panel display, flashing and alternating with the fridge temperature (RM3762 and RM3962 manual).
To reset: After you fix the problem, turn the fridge off and then back on.
E0 E1 E2 E3 E4 LP
The control panel cannot talk to the fridge's power module.
What you can check Turn the fridge off and back on. When to call a tech If E0 comes back, call a tech. A wire, the display or the power module may need service. Find a mobile tech near you
From RM3762 RM3962 Refrigerator Operating Instructions (Form 3313513.016, 9/19/16) , Troubleshooting, Error Codes.
The fridge may have a loose gas valve connection or a fault in its gas system. It may still run on 120-volt power.
What you can check Turn the fridge off and back on. Switch the fridge to electric if you need to keep food cold. When to call a tech Call a tech if E1 stays. The gas valve or gas parts need a pro. Find a mobile tech near you
From RM3762 RM3962 Refrigerator Operating Instructions (Form 3313513.016, 9/19/16) , Troubleshooting, Error Codes.
The fridge cannot read its temperature sensor, or the sensor wiring has a problem.
What you can check Turn the fridge off and back on. When to call a tech If E2 comes back, call a tech. The sensor or its wire may need a fix. Find a mobile tech near you
From RM3762 RM3962 Refrigerator Operating Instructions (Form 3313513.016, 9/19/16) , Troubleshooting, Error Codes.
The maker says the cooling unit has a problem. This one needs service.
When to call a tech Call a tech. The cooling unit needs a pro to check it. Do not keep restarting the fridge. Find a mobile tech near you
From RM3762 RM3962 Refrigerator Operating Instructions (Form 3313513.016, 9/19/16) , Troubleshooting, Error Codes.
The 12-volt power to the fridge is too low or too high. The manual gives about 8 to 18 volts as the safe range.
What you can check Check that your 12-volt battery is charged. Turn the fridge off and back on after you fix the power. When to call a tech If E4 stays with a good battery, call a tech. The charger, wiring or control board may need a look. Find a mobile tech near you
From RM3762 RM3962 Refrigerator Operating Instructions (Form 3313513.016, 9/19/16) , Troubleshooting, Error Codes.
The fridge tried to light the gas and the burner did not light. The display flips between LP and the fridge temperature.
If you smell propane, get everyone out, do not touch switches or flames, and call your gas supplier.
What you can check Make sure your propane tank has gas and the valve is open. Turn the fridge off and back on. You may need to try a few times after a tank change, to clear air from the line. When to call a tech If it still will not light, turn the fridge off and call a tech. The burner may be blocked or dirty. Find a mobile tech near you
From RM3762 RM3962 Refrigerator Operating Instructions (Form 3313513.016, 9/19/16) , Troubleshooting Table.
Dometic RV A/C thermostats (CCC 2 and Single Zone LCD) Where the code shows: On the thermostat screen, in place of the temperature set-point. On the CCC 2 a blinking zone number also shows a fault.
E1 E1 E2 E3 E4 E5 E7 E8 E9 E1 E2 E3 E4 E5
The thermostat cannot talk to any of the air conditioner's power boards. The system shuts down.
What you can check Check the 120-volt breaker or fuse. Check the 12-volt fuse or breaker. When to call a tech If E1 stays after you check the fuses, call a tech. A wire or a control board may have failed. Find a mobile tech near you
From Comfort Control Center 2 Thermostat Operating Instructions (Form 3314149.018, Rev B, 08/16) , LCD Error Code.
The thermostat lost contact with one zone's power board. The screen shows E1 and that zone's number.
What you can check Check the 120-volt breaker or fuse. Check the 12-volt fuse or breaker. When to call a tech Call a tech if it stays. One zone's board or wire may need service. Find a mobile tech near you
From Comfort Control Center 2 Thermostat Operating Instructions (Form 3314149.018, Rev B, 08/16) , LCD Error Code.
The indoor temperature sensor is broken or unplugged. Heat and cooling stop. You can still run the fan by hand.
What you can check Run the fan by hand if you need air moving. When to call a tech Call a tech. The indoor sensor or its wire needs a fix. Find a mobile tech near you
From Comfort Control Center 2 Thermostat Operating Instructions (Form 3314149.018, Rev B, 08/16) , LCD Error Code.
The indoor temperature sensor has a short. Heat and cooling stop. You can still run the fan by hand.
What you can check Run the fan by hand if you need air moving. When to call a tech Call a tech. The indoor sensor or its wire needs a fix. Find a mobile tech near you
From Comfort Control Center 2 Thermostat Operating Instructions (Form 3314149.018, Rev B, 08/16) , LCD Error Code.
The outdoor temperature sensor is broken or unplugged. The heat pump stops. The air conditioner, furnace, heat strip and fan can still run.
When to call a tech Call a tech if you need the heat pump. The outdoor sensor needs a fix. Find a mobile tech near you
From Comfort Control Center 2 Thermostat Operating Instructions (Form 3314149.018, Rev B, 08/16) , LCD Error Code.
The freeze sensor is broken or unplugged. The air conditioner stops. Heat and fan can still run.
What you can check Use the fan or heat if you need them. When to call a tech Call a tech. The freeze sensor needs a fix before cooling comes back. Find a mobile tech near you
From Comfort Control Center 2 Thermostat Operating Instructions (Form 3314149.018, Rev B, 08/16) , LCD Error Code.
The air conditioner's power boards lost 120-volt power. The system shuts down.
What you can check Make sure shore power or the generator is on. Reset the 120-volt breaker or check the fuse. Make sure the power cord is plugged in tight. When to call a tech If power is on and E7 stays, call a tech. A wire or board may need service. Find a mobile tech near you
From Comfort Control Center 2 Thermostat Operating Instructions (Form 3314149.018, Rev B, 08/16) , LCD Error Code.
The setup switches in one zone are set in a way that does not work. Heat and cooling stop in that zone.
When to call a tech Call a tech. The setup switches on the control board need to be set right, then the system reset. Find a mobile tech near you
From Comfort Control Center 2 Thermostat Operating Instructions (Form 3314149.018, Rev B, 08/16) , LCD Error Code.
The setup switches in one zone are set in a way that does not work. Heat and cooling stop in that zone.
When to call a tech Call a tech. The setup switches on the control board need to be set right, then the system reset. Find a mobile tech near you
From Comfort Control Center 2 Thermostat Operating Instructions (Form 3314149.018, Rev B, 08/16) , LCD Error Code.
The thermostat cannot talk to the air conditioner's module board. The screen flips between E1 and the mode. The system shuts down.
What you can check Check the 120-volt breaker or fuse. Check the 12-volt fuse or breaker. When to call a tech If E1 stays, call a tech. A wire or the module board may need service. Find a mobile tech near you
From Single Zone LCD Thermostat User's Guide (Form 3313325.031, 9/1/16) , Error Code.
The indoor sensor is broken or unplugged. Heat and cooling stop. The fan can still run.
When to call a tech Call a tech. The indoor sensor needs a fix. Find a mobile tech near you
From Single Zone LCD Thermostat User's Guide (Form 3313325.031, 9/1/16) , Error Code.
The indoor sensor has a short. Heat and cooling stop. The fan can still run.
When to call a tech Call a tech. The indoor sensor needs a fix. Find a mobile tech near you
From Single Zone LCD Thermostat User's Guide (Form 3313325.031, 9/1/16) , Error Code.
The outdoor sensor is broken or unplugged. The heat pump stops. The air conditioner, furnace and fan can still run.
When to call a tech Call a tech if you need the heat pump. The outdoor sensor needs a fix. Find a mobile tech near you
From Single Zone LCD Thermostat User's Guide (Form 3313325.031, 9/1/16) , Error Code.
The freeze sensor is broken or unplugged. The air conditioner stops. Furnace, heat and fan can still run.
When to call a tech Call a tech. The freeze sensor needs a fix before cooling comes back. Find a mobile tech near you
From Single Zone LCD Thermostat User's Guide (Form 3313325.031, 9/1/16) , Error Code.
Dometic RUC 12-volt fridges Where the code shows: By the error warning light on the display, with the other lights flashing a set number of times.
To reset: Press and hold the ON/OFF button for 2 seconds. A beep means the error is reset. Turning the fridge off and on does not reset it.
1 flash 2 flashes 3 flashes 4 flashes 5 flashes
Your battery voltage is too low for the fridge.
What you can check When to call a tech If it flashes with a charged battery, call a tech. The wires may be too thin or too long, or a part may be bad. Find a mobile tech near you
From RUC5204X, RUC6404X, RUC8404X Installation and Operating Manual (2026) , 12.2 Faults and beeps.
The outside fan pulled too much power.
What you can check Press and hold the ON/OFF button for 2 seconds to reset the error. When to call a tech If it comes back after a reset, call a tech. The fan or its wiring may need service. Find a mobile tech near you
From RUC5204X, RUC6404X, RUC8404X Installation and Operating Manual (2026) , 12.2 Faults and beeps.
The compressor did not start the way it should.
What you can check Press and hold the ON/OFF button for 2 seconds to reset the error. When to call a tech If it comes back after a reset, call a tech. The compressor or its controller may need service. Find a mobile tech near you
From RUC5204X, RUC6404X, RUC8404X Installation and Operating Manual (2026) , 12.2 Faults and beeps.
The compressor controller is working too hard.
What you can check Press and hold the ON/OFF button for 2 seconds to reset the error. When to call a tech If it comes back after a reset, call a tech. The compressor or its controller may need service. Find a mobile tech near you
From RUC5204X, RUC6404X, RUC8404X Installation and Operating Manual (2026) , 12.2 Faults and beeps.
The compressor controller is too hot.
What you can check Make sure nothing blocks the fridge's air vents. Press and hold the ON/OFF button for 2 seconds to reset the error. When to call a tech If it comes back after a reset, call a tech. The condenser may need cleaning or a part may need service. Find a mobile tech near you
From RUC5204X, RUC6404X, RUC8404X Installation and Operating Manual (2026) , 12.2 Faults and beeps.