A little help for the road ahead.Free to browse, with no sign-up

RV error codes

Truma RV water heater and furnace error codes.

We list 42 Truma codes from the maker’s own manuals. Find yours to see what it means, what you can safely check, and when to call a tech. Need a tech now?

If you smell propane, see smoke, or a CO alarm goes off, turn it off, get everyone out, and call 911.

Truma AquaGo tankless water heaters

Where the code shows: A yellow light flashes fast twice, and a red light under the rocker switch blinks short and long flashes in a pattern every 3 seconds; with a CP plus panel the number shows on the screen, such as E or W and the number.

To reset: Turn the heater off, wait 5 seconds, then turn it on again; if the code stays, contact a Truma service center.

1

No flame

AquaGo basic, comfort and comfort plus

The heater tried to light three times. It could not make a flame.

If you smell propane, turn off the tank valve, get everyone out of your RV, and call for help from outside.

What you can check

  • Make sure the propane tank has gas and the tank valve is open.
  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code comes back after a reset, call a tech. The igniter or gas valve may need service. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

2

Over temperature switch open

AquaGo basic, comfort and comfort plus

A safety switch on the burner or the exhaust is open or came loose.

What you can check

  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code comes back after a reset, call a tech. A tech needs to check the safety switches. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

3

Exhaust pressure switch problem

AquaGo basic, comfort and comfort plus

The flue fan did not push enough air out, or the switch is stuck. The exhaust may be blocked, or a part is bad.

What you can check

  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code comes back after a reset, call a tech. A tech can check the exhaust, the fan, and the switch. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

4

Water over temperature switch open

AquaGo basic, comfort and comfort plus

The water got too hot, over 185 degrees F, and a safety switch opened.

What you can check

  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code comes back after a reset, call a tech. A tech needs to find out why the water got so hot. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

5

Flame seen at the wrong time

AquaGo basic, comfort and comfort plus

The heater saw a flame when there should be none. This can happen before it lights or after the gas shuts off.

If you smell propane, turn off the tank valve, get everyone out of your RV, and call for help from outside.

What you can check

  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code comes back after a reset, call a tech. The flame sensor or gas valve may be bad. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

6

Gas valve safety circuit error

AquaGo basic, comfort and comfort plus

The heater asked for heat, but the gas could not flow. One of the safety switches is open or came loose.

What you can check

  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code comes back after a reset, call a tech. A tech can check the safety switches. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

7

Burner computer error

AquaGo basic, comfort and comfort plus

The burner's control chip found a problem in its own memory.

What you can check

  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code comes back after a reset, call a tech. The control board may need to be replaced. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

9

Water outlet sensor problem

AquaGo basic, comfort and comfort plus

The sensor that checks hot water leaving the heater is shorted or came loose.

What you can check

  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code comes back after a reset, call a tech. A tech can check the sensor and its wires. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

10

Safety circuit error

AquaGo basic, comfort and comfort plus

The heater asked for heat, but the gas did not flow because a valve signal did not turn on.

What you can check

  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code comes back after a reset, call a tech. A tech can check the gas valve and control board. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

11

Control chip watchdog error

AquaGo basic, comfort and comfort plus

The heater asked for heat, but the control chip did not let the gas flow.

What you can check

  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code comes back after a reset, call a tech. The control board may need service. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

13

Gas valve short circuit

AquaGo basic, comfort and comfort plus

The shut-off part of the gas valve pulled too much power, so the heater shut it off.

What you can check

  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code comes back after a reset, call a tech. The gas valve may need to be replaced. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

20

Water inlet sensor problem

AquaGo basic, comfort and comfort plus

The sensor that checks cold water coming in is shorted, came loose, or reads colder than 14 degrees F.

What you can check

  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code comes back after a reset, call a tech. A tech can check the sensor and its wires. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

21

Circulation line sensor problem

AquaGo basic, comfort and comfort plus

The sensor on the circulation line is shorted, came loose, or reads colder than 14 degrees F.

What you can check

  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code comes back after a reset, call a tech. A tech can check the sensor and its wires. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

22

Gas valve control problem

AquaGo basic, comfort and comfort plus

The part of the gas valve that sets the flame size is shorted or came loose.

What you can check

  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code comes back after a reset, call a tech. The gas valve or its wires may need service. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

23

Voltage too high

AquaGo basic, comfort and comfort plus

Your RV's 12-volt power is over 16.4 volts. That is too high for the heater.

What you can check

  • Check your 12-volt battery and your battery charger or converter.

When to call a tech

If the voltage stays too high, call a tech. The charger or converter may be bad. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

24

Voltage too low

AquaGo basic, comfort and comfort plus

Your RV's 12-volt power is under 10 volts. That is too low for the heater.

What you can check

  • Check that your 12-volt battery is charged.
  • Turn on shore power or the generator to charge it.

When to call a tech

If the battery is good and the code stays, call a tech. A tech can check the power wires. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

26

Circulation pump power problem

AquaGo basic, comfort and comfort plus

The circulation pump is pulling too much or too little power.

What you can check

  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code comes back after a reset, call a tech. The pump may need to be replaced. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

27

Water pump running dry

AquaGo basic, comfort and comfort plus

The pump is not moving water. The water system may not be full, or air may be stuck in the lines.

What you can check

  • Make sure your fresh water tank has water.
  • Open each hot water faucet, one at a time, until the air is out.
  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code stays after the water system is full, call a tech. The pump may need service. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

28

Gas pressure too low

AquaGo basic, comfort and comfort plus

The heater is not getting enough gas from your RV's propane system.

If you smell propane, turn off the tank valve, get everyone out of your RV, and call for help from outside.

What you can check

  • Make sure the propane tank has gas and the tank valve is open.

When to call a tech

If the tank is full and the code stays, call a tech. The propane system may need a check. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

29

Too much hot water asked for

AquaGo basic, comfort and comfort plus

You are using more hot water than the heater can make at one time.

What you can check

  • Use fewer hot water faucets or showers at the same time.

When to call a tech

If you get this code with only one faucet on, call a tech. The heater may need a check. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

30

Risk of freezing

AquaGo basic, comfort and comfort plus

The air inside the heater is below 27 degrees F. The heater could freeze.

What you can check

  • If you can, drain the heater.
  • If you cannot drain it, keep it on in Eco or Comfort mode.

When to call a tech

If the heater was damaged by ice or leaks after it thaws, call a tech. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

32

Freeze kit power too low

AquaGo basic, comfort and comfort plus

The antifreeze kit is pulling too little power. A wire may be broken.

What you can check

  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code comes back after a reset, call a tech. A tech can check the antifreeze kit wires. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

33

Freeze kit power too high

AquaGo basic, comfort and comfort plus

The antifreeze kit is pulling too much power. A wire may be shorted.

What you can check

  • Turn the heater off, wait 5 seconds, then turn it on again.

When to call a tech

If the code comes back after a reset, call a tech. A tech can check the antifreeze kit wires. Find a mobile tech near you

From Truma Water Heater Model AquaGo Error Codes (Appendix A), Appendix A, Error Codes.

Truma Combi furnace and water heater

Where the code shows: On the CP plus control panel as a W (warning) or E (malfunction) with the code number and an H for the furnace.

To reset: Fix the cause, then tap the rotary button on the CP plus to restart the furnace; this can take a few minutes.

112

Gas off or furnace too hot

Combi with the CP plus panel

The Combi is not getting gas, or it got too hot and shut off.

If you smell propane, turn off the tank valve, get everyone out of your RV, and call for help from outside.

What you can check

  • Make sure the propane tank has gas.
  • Make sure the gas shut-off valve is open.
  • If it got too hot, turn the furnace off and let it cool. Then check that the warm air outlets and the air intake are not blocked, and turn it on again.

When to call a tech

If the code comes back after these checks, call a tech. The Combi may need service. Find a mobile tech near you

From Troubleshooting chart (Truma Combi furnace), Troubleshooting chart (Truma Combi furnace).

121

Gas off or furnace too hot

Combi with the CP plus panel

The Combi is not getting gas, or it got too hot and shut off.

If you smell propane, turn off the tank valve, get everyone out of your RV, and call for help from outside.

What you can check

  • Make sure the propane tank has gas.
  • Make sure the gas shut-off valve is open.
  • If it got too hot, turn the furnace off and let it cool. Then check that the warm air outlets and the air intake are not blocked, and turn it on again.

When to call a tech

If the code comes back after these checks, call a tech. The Combi may need service. Find a mobile tech near you

From Troubleshooting chart (Truma Combi furnace), Troubleshooting chart (Truma Combi furnace).

202

Gas off or furnace too hot

Combi with the CP plus panel

The Combi is not getting gas, or it got too hot and shut off.

If you smell propane, turn off the tank valve, get everyone out of your RV, and call for help from outside.

What you can check

  • Make sure the propane tank has gas.
  • Make sure the gas shut-off valve is open.
  • If it got too hot, turn the furnace off and let it cool. Then check that the warm air outlets and the air intake are not blocked, and turn it on again.

When to call a tech

If the code comes back after these checks, call a tech. The Combi may need service. Find a mobile tech near you

From Troubleshooting chart (Truma Combi furnace), Troubleshooting chart (Truma Combi furnace).

211

Gas off or furnace too hot

Combi with the CP plus panel

The Combi is not getting gas, or it got too hot and shut off.

If you smell propane, turn off the tank valve, get everyone out of your RV, and call for help from outside.

What you can check

  • Make sure the propane tank has gas.
  • Make sure the gas shut-off valve is open.
  • If it got too hot, turn the furnace off and let it cool. Then check that the warm air outlets and the air intake are not blocked, and turn it on again.

When to call a tech

If the code comes back after these checks, call a tech. The Combi may need service. Find a mobile tech near you

From Troubleshooting chart (Truma Combi furnace), Troubleshooting chart (Truma Combi furnace).

122

Air or exhaust blocked, or gas off

Combi with the CP plus panel

The air going in or the exhaust going out is blocked. The gas may also be off, or it got too hot.

If you smell propane, turn off the tank valve, get everyone out of your RV, and call for help from outside.

What you can check

  • Look at the air and exhaust openings outside. Clear leaves, ice, or slush.
  • Make sure the gas shut-off valve is open.
  • If it got too hot, turn the furnace off and let it cool. Check the warm air outlets and air intake, then turn it on again.

When to call a tech

If the code comes back, call a tech. The gas pressure part or the control board may need service. Find a mobile tech near you

From Troubleshooting chart (Truma Combi furnace), Troubleshooting chart (Truma Combi furnace).

212

Air or exhaust blocked, or gas off

Combi with the CP plus panel

The air going in or the exhaust going out is blocked. The gas may also be off, or it got too hot.

If you smell propane, turn off the tank valve, get everyone out of your RV, and call for help from outside.

What you can check

  • Look at the air and exhaust openings outside. Clear leaves, ice, or slush.
  • Make sure the gas shut-off valve is open.
  • If it got too hot, turn the furnace off and let it cool. Check the warm air outlets and air intake, then turn it on again.

When to call a tech

If the code comes back, call a tech. The gas pressure part or the control board may need service. Find a mobile tech near you

From Troubleshooting chart (Truma Combi furnace), Troubleshooting chart (Truma Combi furnace).

17

Hot water on with empty tank

Combi with the CP plus panel

You turned on hot water mode, but the water tank is empty.

What you can check

  • Turn the furnace off and let it cool.
  • Fill the water tank (boiler) with water.

When to call a tech

If the code comes back with the tank full, call a tech. Find a mobile tech near you

From Troubleshooting chart (Truma Combi furnace), Troubleshooting chart (Truma Combi furnace).

18

Warm air outlet or air intake blocked

Combi with the CP plus panel

The warm air outlets or the air intake are blocked.

What you can check

  • Check each warm air outlet to see that it is open.
  • Clear anything blocking the air intake.

When to call a tech

If the code stays after you clear the openings, call a tech. Find a mobile tech near you

From Troubleshooting chart (Truma Combi furnace), Troubleshooting chart (Truma Combi furnace).

24

Battery getting low

Combi with the CP plus panel

Your 12-volt battery is getting low, under 10.4 volts.

What you can check

  • Charge your 12-volt battery.
  • Turn on shore power or the generator.

When to call a tech

If the battery is good and the code stays, call a tech. A tech can check the power wires. Find a mobile tech near you

From Troubleshooting chart (Truma Combi furnace), Troubleshooting chart (Truma Combi furnace).

43

Voltage too high

Combi with the CP plus panel

Your RV's 12-volt power is over 16.4 volts.

What you can check

  • Check your battery and your battery charger or converter.

When to call a tech

If the voltage stays too high, call a tech. The charger or converter may be bad. Find a mobile tech near you

From Troubleshooting chart (Truma Combi furnace), Troubleshooting chart (Truma Combi furnace).

44

Battery too low

Combi with the CP plus panel

Your 12-volt battery is under 10 volts. The Combi cannot run well.

What you can check

  • Charge your 12-volt battery.
  • If the battery is old, it may need to be replaced.

When to call a tech

If a good battery still gives this code, call a tech. Find a mobile tech near you

From Troubleshooting chart (Truma Combi furnace), Troubleshooting chart (Truma Combi furnace).

45

No 120-volt power or overheated

Combi with the CP plus panel

On Combi eco plus and comfort plus only. The Combi has no 120-volt power, or its overheat guard tripped.

What you can check

  • Make sure shore power or the generator is on.
  • Check that the RV breaker has not tripped.

When to call a tech

If power is on and the code stays, call a tech. The overheat guard needs service. Find a mobile tech near you

From Troubleshooting chart (Truma Combi furnace), Troubleshooting chart (Truma Combi furnace).

255

No 12-volt power or panel link lost

Combi with the CP plus panel

The Combi has no 12-volt power, or it lost its link to the control panel.

What you can check

  • Check that your 12-volt battery is charged.
  • Check the fuse and breaker for the Combi.

When to call a tech

If power is good and the code stays, call a tech. The panel cable may be bad. Find a mobile tech near you

From Troubleshooting chart (Truma Combi furnace), Troubleshooting chart (Truma Combi furnace).

Questions people ask.

What does Truma code 1 mean?

The heater tried to light three times. It could not make a flame. If the code comes back after a reset, call a tech. The igniter or gas valve may need service.

What does Truma code 2 mean?

A safety switch on the burner or the exhaust is open or came loose. If the code comes back after a reset, call a tech. A tech needs to check the safety switches.

What does Truma code 3 mean?

The flue fan did not push enough air out, or the switch is stuck. The exhaust may be blocked, or a part is bad. If the code comes back after a reset, call a tech. A tech can check the exhaust, the fan, and the switch.

What does Truma code 4 mean?

The water got too hot, over 185 degrees F, and a safety switch opened. If the code comes back after a reset, call a tech. A tech needs to find out why the water got so hot.

Where these codes come from.

We read each Truma manual below and wrote the codes in plain words. If your manual says something different, follow your manual.

Other brands: Norcold · Lippert · Onan · Furrion · Dometic · Suburban · Atwood · Search all codes

RV Repair Connect is not part of Truma. Brand names belong to their owners.