A little help for the road ahead.Free to browse, with no sign-up

RV error codes

Onan RV generator error codes.

We list 47 Onan codes from the maker’s own manuals. Find yours to see what it means, what you can safely check, and when to call a tech. Need a tech now?

If you smell propane, see smoke, or a CO alarm goes off, turn it off, get everyone out, and call 911.

Onan RV generators

Where the code shows: On the status light in the start/stop switch (at the generator and the remote panel). One flash is code 1, two is code 2, three means read a two-digit code, four is code 4. Press STOP/PRIME once to see the two-digit code. The model family (like HGJAB) is on the nameplate on the generator.

To reset: The code stops blinking after 5 minutes. Press STOP/PRIME 3 times within 5 seconds to see it again. The last fault keeps blinking even after it is fixed.

1

Engine too hot (diesel)

6,000 to 8,000-watt diesel (HDKAH)

Your engine got too hot. The coolant ran over 239 degrees F for 10 seconds.

What you can check

  • Let the engine cool all the way down first.
  • When it is cool, check the coolant level.
  • Make sure nothing blocks the air openings on the bottom of the generator.
  • Turn off some things, like the air conditioner or battery charger.

When to call a tech

If the code comes back, call a mobile RV tech. There may be a coolant leak or a clogged heat exchanger. Find a mobile tech near you

From Operator Manual, Onan Generator Set for RV HDKAH (Spec A-T), A046L053 Issue 6, 6.2.1 Code 1.

2

Low oil pressure

2,800-watt gas and propane (HGJBB), 5,500 and 7,000-watt gas and propane (HGJAA, HGJAB, HGJAC), 6,000 to 8,000-watt diesel (HDKAH)

The generator thinks the oil pressure is too low. It shut down to protect the engine.

What you can check

  • Check the oil level with the dipstick. Add oil if it is low.
  • The manual says to drain extra oil if the level is above the full mark.

When to call a tech

If the oil level is right and the code comes back, call a mobile RV tech. Do not keep running the generator. Find a mobile tech near you

From Operator Manual, Onan Generator Set for RV HGJBB (Spec A-B), A031C171 Issue 8, 6.2.1 Code 2 - Low Oil Pressure.

3

Service fault (read the second code)

2,800-watt gas and propane (HGJBB), 5,500 and 7,000-watt gas and propane (HGJAA, HGJAB, HGJAC), 6,000 to 8,000-watt diesel (HDKAH)

Three blinks mean a service fault. There is a second code with two digits.

What you can check

  • Press STOP/PRIME on the start switch once to see the two-digit code.
  • Press it again to stop the blinking.

When to call a tech

Look up the two-digit code. Do not read it as code 33. Find a mobile tech near you

From Operator Manual, Onan Generator Set for RV HGJBB (Spec A-B), A031C171 Issue 8, 6.2 Fault Codes.

4

Cranked too long, no start

2,800-watt gas and propane (HGJBB), 5,500 and 7,000-watt gas and propane (HGJAA, HGJAB, HGJAC), 6,000 to 8,000-watt diesel (HDKAH)

The engine cranked for more than 30 seconds and did not start.

What you can check

  • Check that the fuel tank has fuel. The generator pickup may sit higher than the RV engine's.
  • If you run on propane, check that the tank has gas.
  • Hold the start switch at STOP/PRIME for 30 seconds to prime the fuel system.
  • Check the oil level.

When to call a tech

If it still will not start, call a mobile RV tech. It may need a new spark plug, fuel filter or air filter, or a fuel fix. Find a mobile tech near you

From Operator Manual, Onan Generator Set for RV HGJBB (Spec A-B), A031C171 Issue 8, 6.2.3 Code 4 - Over Crank.

4

Cranked too long, no start

7,000-watt inverter (HGLCA)

The engine cranked for more than 15 seconds and did not start.

What you can check

  • Check that the fuel tank has fuel. The generator pickup may sit higher than the RV engine's.
  • If you run on propane, check that the tank has gas.
  • Hold the start switch at STOP/PRIME for 30 seconds to prime the fuel system.

When to call a tech

If it still will not start, call a mobile RV tech. Find a mobile tech near you

From Operator Manual, Onan Generator Set for RV HGLCA (Spec A), A079E225 Issue 1, 6.2.2 Code 4 - Over Crank.

13

Voltage too low

2,800-watt gas and propane (HGJBB), 5,500 and 7,000-watt gas and propane (HGJAA, HGJAB, HGJAC), 6,000 to 8,000-watt diesel (HDKAH), 7,000-watt inverter (HGLCA)

The control cannot keep the power at the right voltage. Too many things may be running.

What you can check

  • Turn off some things, like the air conditioner or battery charger.

When to call a tech

If the code comes back with a light load, call a mobile RV tech. Find a mobile tech near you

From Operator Manual, Onan Generator Set for RV HGJBB (Spec A-B), A031C171 Issue 8, 6.2.5 Code 13 - Under Voltage.

15

Engine running too slow

2,800-watt gas and propane (HGJBB), 5,500 and 7,000-watt gas and propane (HGJAA, HGJAB, HGJAC), 6,000 to 8,000-watt diesel (HDKAH), 7,000-watt inverter (HGLCA)

The engine speed control cannot hold the right speed. Too many things may be running.

What you can check

  • Turn off some things, like the air conditioner or battery charger.

When to call a tech

If the code comes back with a light load, call a mobile RV tech. Find a mobile tech near you

From Operator Manual, Onan Generator Set for RV HGJBB (Spec A-B), A031C171 Issue 8, 6.2.7 Code 15 - Under Frequency.

22

Governor actuator overload

5,500 and 7,000-watt gas and propane (HGJAA, HGJAB, HGJAC), 6,000 to 8,000-watt diesel (HDKAH)

The engine has worked at full effort for too long.

What you can check

  • Turn off some things, like the air conditioner or battery charger.
  • Make sure nothing blocks the exhaust.

When to call a tech

If the code comes back, call a mobile RV tech. The air filter or exhaust may need work. Find a mobile tech near you

From Operator Manual, Onan Generator Set for RV HDKAH (Spec A-T), A046L053 Issue 6, 6.2.10 Code 22.

29

Battery voltage too high

2,800-watt gas and propane (HGJBB), 5,500 and 7,000-watt gas and propane (HGJAA, HGJAB, HGJAC), 6,000 to 8,000-watt diesel (HDKAH), 7,000-watt inverter (HGLCA)

The voltage at the generator's battery is too high.

What you can check

  • Check that your 12-volt batteries are wired side by side (12 volts), not in a row (24 volts).
  • Turn the battery charge rate down if you can.

When to call a tech

If the code comes back, call a mobile RV tech to check the battery wiring and charger. Find a mobile tech near you

From Operator Manual, Onan Generator Set for RV HGJBB (Spec A-B), A031C171 Issue 8, 6.2.9 Code 29 - High Battery Voltage.

32

Slow cranking

2,800-watt gas and propane (HGJBB), 5,500 and 7,000-watt gas and propane (HGJAA, HGJAB, HGJAC), 6,000 to 8,000-watt diesel (HDKAH)

The engine cranked too slowly to start. The battery is often the cause.

What you can check

  • Check that the battery is charged.
  • Check that the battery cable ends are clean and tight.

When to call a tech

If the battery is good and the code comes back, call a mobile RV tech. Find a mobile tech near you

From Operator Manual, Onan Generator Set for RV HGJBB (Spec A-B), A031C171 Issue 8, 6.2.11 Code 32 - Low Cranking Speed.

36

Engine stopped on its own

2,800-watt gas and propane (HGJBB), 5,500 and 7,000-watt gas and propane (HGJAA, HGJAB, HGJAC), 6,000 to 8,000-watt diesel (HDKAH)

The engine stopped and the control did not tell it to.

What you can check

  • Check that the fuel tank has fuel. The generator pickup may sit higher than the RV engine's.
  • If you run on propane, check that the tank has gas.
  • Hold the start switch at STOP/PRIME for 30 seconds to prime the fuel system (gas and diesel models).

When to call a tech

If it keeps happening, call a mobile RV tech. It may need a spark plug, air filter or other repair. Find a mobile tech near you

From Operator Manual, Onan Generator Set for RV HGJBB (Spec A-B), A031C171 Issue 8, 6.2.13 Code 36 - Engine Stopped.

38

Overload (field overload)

2,800-watt gas and propane (HGJBB), 5,500 and 7,000-watt gas and propane (HGJAA, HGJAB, HGJAC), 6,000 to 8,000-watt diesel (HDKAH), 7,000-watt inverter (HGLCA)

Something you run pulls too much power, or an appliance may be failing.

What you can check

  • Turn off some things, like the air conditioner or battery charger.

When to call a tech

If it keeps happening with a light load, call a mobile RV tech to check the generator and appliances. Find a mobile tech near you

From Operator Manual, Onan Generator Set for RV HGJBB (Spec A-B), A031C171 Issue 8, 6.2.15 Code 38 - Over Current.

57

Over prime, or propane pressure or valve fault

7,000-watt inverter (HGLCA)

Priming ran too long, or the propane pressure or propane valve is wrong.

If you smell propane, leave the RV, stay away from flames and sparks, and call for help.

What you can check

  • Check that nothing is holding the start switch in the STOP/PRIME position.

When to call a tech

Call a mobile RV tech. The propane system may need service. Find a mobile tech near you

From Operator Manual, Onan Generator Set for RV HGLCA (Spec A), A079E225 Issue 1, 6.2.22 Code 57.

Questions people ask.

What does Onan code 1 mean?

Your engine got too hot. The coolant ran over 239 degrees F for 10 seconds. If the code comes back, call a mobile RV tech. There may be a coolant leak or a clogged heat exchanger.

What does Onan code 1 mean?

The engine oil got too hot, so the generator shut down. If the code comes back after it cools, call a mobile RV tech.

What does Onan code 2 mean?

The generator thinks the oil pressure is too low. It shut down to protect the engine. If the oil level is right and the code comes back, call a mobile RV tech. Do not keep running the generator.

What does Onan code 3 mean?

Three blinks mean a service fault. There is a second code with two digits. Look up the two-digit code. Do not read it as code 33.

Where these codes come from.

We read each Onan manual below and wrote the codes in plain words. If your manual says something different, follow your manual.

Other brands: Norcold · Lippert · Truma · Furrion · Dometic · Suburban · Atwood · Search all codes

RV Repair Connect is not part of Cummins Onan. Brand names belong to their owners.