Furrion Chill A/C (wall thermostat codes)

Where the code shows: On the LCD screen of the wall thermostat, such as E1 or lo.

E1

Control box indoor sensor failed

Chill A/C with the FACW10ESSA-BL or FACW10ESSA2-BL wall thermostat

The temperature sensor in the air conditioner's control box is not working. The air conditioner shuts down.

When to call a tech

Call a tech. The sensor or its wire needs a check, and the air conditioner stays off until it is fixed. Find a mobile tech near you

From Furrion Thermostat Model FACW10ESSA-BL Instruction Manual, LCD Error Code table.

E2

Evaporator sensor failed

Chill A/C with the FACW10ESSA-BL or FACW10ESSA2-BL wall thermostat

The sensor on the cooling coil (evaporator) is not working. The air conditioner shuts down.

When to call a tech

Call a tech. The sensor or its wire needs a check, and the air conditioner stays off until it is fixed. Find a mobile tech near you

From Furrion Thermostat Model FACW10ESSA-BL Instruction Manual, LCD Error Code table.

E3

Thermostat lost link to control box

Chill A/C with the FACW10ESSA-BL or FACW10ESSA2-BL wall thermostat

The wall thermostat and the control box on the air conditioner cannot talk to each other. The air conditioner shuts down.

When to call a tech

Call a tech. The thermostat wire or the control box may need a check. Find a mobile tech near you

From Furrion Thermostat Model FACW10ESSA-BL Instruction Manual, LCD Error Code table.

E5

Outdoor air sensor failed

Chill A/C with the FACW10ESSA2-BL wall thermostat

The sensor that reads the outside air temperature is not working. The air conditioner shuts down.

When to call a tech

Call a tech. The sensor or its wire needs a check, and the air conditioner stays off until it is fixed. Find a mobile tech near you

From Furrion Thermostat Model FACW10ESSA2-BL Quick Guide, LCD Error Code table.

lo

12-volt power too low

Chill A/C with the FACW10ESSA-BL or FACW10ESSA2-BL wall thermostat

Your RV's 12-volt power is too low for the air conditioner. It shuts down.

What you can check

  • Check that your 12-volt battery is charged.
  • Turn on shore power or the generator so the converter can charge the battery.

When to call a tech

If the battery is good and the code stays, call a tech. A tech can check the 12-volt wiring. Find a mobile tech near you

From Furrion Thermostat Model FACW10ESSA-BL Instruction Manual, LCD Error Code table.

Furrion 12-volt fridges

Where the code shows: On the 10.6 cu. ft. model, an LED on the panel blinks the code number or the battery icon flashes; on the 16.2 cu. ft. model, a two-letter code shows when the fridge is in fault mode.

To reset: The manual says to do a hard reset first: turn off shore power, battery power, and solar power, then turn them back on.

EL

Battery power low

10.6 cu. ft. FCR11DCGTA (battery icon flashes slowly)

The power going into the fridge is low, between 9.1 and 10.6 volts.

What you can check

  • Check that your 12-volt battery is charged.
  • Turn on shore power or the generator, or check your solar and converter.

When to call a tech

If the battery is good and the code stays, call a tech. A tech can check the wires and the charger. Find a mobile tech near you

From Furrion Arctic 10.6 Cu. Ft. 12V(DC) RV Refrigerator Instruction Manual (CCD-0008594), Troubleshooting, Error Codes table.

OU

Battery power too high

16.2 cu. ft. frost-free (SRM-418CBG-E, SRM-418CBG-ES)

The fridge shut the compressor off because the power was too high, above 11 volts after a battery change.

What you can check

  • Wait 5 minutes and see if the code clears.

When to call a tech

If the code does not clear, call a tech. The charger or converter may be sending too much power. Find a mobile tech near you

From 16.2 Cu. Ft. 12V Built-In Vehicle Frost-Free Refrigerator-Freezer Troubleshooting and Service Manual (CCD-0007855), Fault Display, Error Codes table.

Furrion tankless water heater

Where the code shows: On the display of the control panel, such as E1; the heater shuts off when it finds an unsafe problem.

To reset: To reset after a lockout, turn the hot water faucet off and back on.

E1

No flame

F2GWH tankless

The heater could not light, or the flame went out while it was lighting. After two tries it locks out.

If you smell propane, turn off the tank valve, get everyone out of your RV, and call for help from outside.

What you can check

  • Make sure the propane tank has gas and the tank valve is open.
  • To reset, turn the hot water faucet off and back on.

When to call a tech

If the code comes back, call a tech. The igniter, its wires, or the gas pressure may need service. Find a mobile tech near you

From Furrion Tankless Water Heater Model F2GWH User Manual (CCD-0005833), Troubleshooting.

E2

Flame lost while running

F2GWH tankless

The flame went out while the heater was running. A buzzer sounds. The heater locks out.

If you smell propane, turn off the tank valve, get everyone out of your RV, and call for help from outside.

What you can check

  • Make sure the propane tank has gas and the tank valve is open.
  • To reset, turn the hot water faucet off and back on.

When to call a tech

If the code comes back, call a tech. The igniter or the gas supply may need service. Find a mobile tech near you

From Furrion Tankless Water Heater Model F2GWH User Manual (CCD-0005833), Troubleshooting.

E8

Air pressure switch problem

F2GWH tankless

The air switch did not sense air flow. The blower may be bad, or the air intake or exhaust may be blocked.

What you can check

  • With the heater off, look at the outside air vents and the exhaust. Clear leaves, mud, and bug nests.

When to call a tech

If the vents are clear and the code stays, call a tech. The blower or the switch may need service. Find a mobile tech near you

From Furrion Tankless Water Heater Model F2GWH User Manual (CCD-0005833), Troubleshooting.

Questions people ask.

What does Furrion code E1 mean?

The temperature sensor in the air conditioner's control box is not working. The air conditioner shuts down. Call a tech. The sensor or its wire needs a check, and the air conditioner stays off until it is fixed.

What does Furrion code E2 mean?

The sensor on the cooling coil (evaporator) is not working. The air conditioner shuts down. Call a tech. The sensor or its wire needs a check, and the air conditioner stays off until it is fixed.

What does Furrion code E3 mean?

The wall thermostat and the control box on the air conditioner cannot talk to each other. The air conditioner shuts down. Call a tech. The thermostat wire or the control box may need a check.

What does Furrion code E4 mean?

The sensor on the outdoor coil is not working. The air conditioner shuts down. Call a tech. The sensor or its wire needs a check, and the air conditioner stays off until it is fixed.

Where these codes come from.

We read each Furrion manual below and wrote the codes in plain words. If your manual says something different, follow your manual.

Other brands: Norcold · Lippert · Onan · Truma · Dometic · Suburban · Atwood · Search all codes