Furrion Chill A/C (wall thermostat codes) Where the code shows: On the LCD screen of the wall thermostat, such as E1 or lo.
E1 E2 E3 E4 E5 E6 lo
The temperature sensor in the air conditioner's control box is not working. The air conditioner shuts down.
When to call a tech Call a tech. The sensor or its wire needs a check, and the air conditioner stays off until it is fixed. Find a mobile tech near you
From Furrion Thermostat Model FACW10ESSA-BL Instruction Manual , LCD Error Code table.
The sensor on the cooling coil (evaporator) is not working. The air conditioner shuts down.
When to call a tech Call a tech. The sensor or its wire needs a check, and the air conditioner stays off until it is fixed. Find a mobile tech near you
From Furrion Thermostat Model FACW10ESSA-BL Instruction Manual , LCD Error Code table.
The wall thermostat and the control box on the air conditioner cannot talk to each other. The air conditioner shuts down.
When to call a tech Call a tech. The thermostat wire or the control box may need a check. Find a mobile tech near you
From Furrion Thermostat Model FACW10ESSA-BL Instruction Manual , LCD Error Code table.
The sensor on the outdoor coil is not working. The air conditioner shuts down.
When to call a tech Call a tech. The sensor or its wire needs a check, and the air conditioner stays off until it is fixed. Find a mobile tech near you
From Furrion Thermostat Model FACW10ESSA2-BL Quick Guide , LCD Error Code table.
The sensor that reads the outside air temperature is not working. The air conditioner shuts down.
When to call a tech Call a tech. The sensor or its wire needs a check, and the air conditioner stays off until it is fixed. Find a mobile tech near you
From Furrion Thermostat Model FACW10ESSA2-BL Quick Guide , LCD Error Code table.
The temperature sensor inside the wall thermostat is not working. The air conditioner shuts down.
When to call a tech Call a tech. The thermostat may need to be replaced. Find a mobile tech near you
From Furrion Thermostat Model FACW10ESSA-BL Instruction Manual , LCD Error Code table.
Your RV's 12-volt power is too low for the air conditioner. It shuts down.
What you can check Check that your 12-volt battery is charged. Turn on shore power or the generator so the converter can charge the battery. When to call a tech If the battery is good and the code stays, call a tech. A tech can check the 12-volt wiring. Find a mobile tech near you
From Furrion Thermostat Model FACW10ESSA-BL Instruction Manual , LCD Error Code table.
Furrion 12-volt fridges Where the code shows: On the 10.6 cu. ft. model, an LED on the panel blinks the code number or the battery icon flashes; on the 16.2 cu. ft. model, a two-letter code shows when the fridge is in fault mode.
To reset: The manual says to do a hard reset first: turn off shore power, battery power, and solar power, then turn them back on.
E1 E2 E3 E4 E5 E12 E13 E14 EL EH UC RS CS FS FD FF ES LU OU
The power going to the compressor is too low or too high.
What you can check Check that your 12-volt battery is charged and not too low. Wait 5 minutes to see if it clears. When to call a tech If the code stays, call a tech. The wiring or the control board may need service. Find a mobile tech near you
From Furrion Arctic 10.6 Cu. Ft. 12V(DC) RV Refrigerator Instruction Manual (CCD-0008594) , Troubleshooting, Error Codes table.
The fan inside the freezer is not working.
When to call a tech Call a tech. The fan needs to be checked. Find a mobile tech near you
From Furrion Arctic 10.6 Cu. Ft. 12V(DC) RV Refrigerator Instruction Manual (CCD-0008594) , Troubleshooting, Error Codes table.
The compressor motor is stuck, or the pressure in the system is too high.
When to call a tech Call a tech. The compressor needs to be checked. Find a mobile tech near you
From Furrion Arctic 10.6 Cu. Ft. 12V(DC) RV Refrigerator Instruction Manual (CCD-0008594) , Troubleshooting, Error Codes table.
The compressor is running at the wrong speed.
When to call a tech Call a tech. The compressor or its control board may need service. Find a mobile tech near you
From Furrion Arctic 10.6 Cu. Ft. 12V(DC) RV Refrigerator Instruction Manual (CCD-0008594) , Troubleshooting, Error Codes table.
The compressor's control board is too hot.
What you can check Make sure nothing blocks the air vents around the fridge. When to call a tech If the code comes back, call a tech. The control board may need service. Find a mobile tech near you
From Furrion Arctic 10.6 Cu. Ft. 12V(DC) RV Refrigerator Instruction Manual (CCD-0008594) , Troubleshooting, Error Codes table.
The compressor's control board has a hardware problem.
When to call a tech Call a tech. The control board may need to be replaced. Find a mobile tech near you
From Furrion Arctic 10.6 Cu. Ft. 12V(DC) RV Refrigerator Instruction Manual (CCD-0008594) , Troubleshooting, Error Codes table.
The temperature sensor in the fridge part is not working.
When to call a tech Call a tech. The sensor needs to be replaced. Find a mobile tech near you
From Furrion Arctic 10.6 Cu. Ft. 12V(DC) RV Refrigerator Instruction Manual (CCD-0008594) , Troubleshooting, Error Codes table.
The temperature sensor in the freezer part is not working.
When to call a tech Call a tech. The sensor needs to be replaced. Find a mobile tech near you
From Furrion Arctic 10.6 Cu. Ft. 12V(DC) RV Refrigerator Instruction Manual (CCD-0008594) , Troubleshooting, Error Codes table.
The power going into the fridge is low, between 9.1 and 10.6 volts.
What you can check Check that your 12-volt battery is charged. Turn on shore power or the generator, or check your solar and converter. When to call a tech If the battery is good and the code stays, call a tech. A tech can check the wires and the charger. Find a mobile tech near you
From Furrion Arctic 10.6 Cu. Ft. 12V(DC) RV Refrigerator Instruction Manual (CCD-0008594) , Troubleshooting, Error Codes table.
The power going into the fridge is too high, over 17 volts.
What you can check Check your battery charger, converter, and solar system for faults. When to call a tech If the code stays, call a tech. The charger or converter may be bad. Find a mobile tech near you
From Furrion Arctic 10.6 Cu. Ft. 12V(DC) RV Refrigerator Instruction Manual (CCD-0008594) , Troubleshooting, Error Codes table.
The fridge parts cannot talk to each other, or a part does not match the model.
When to call a tech Call a tech. A tech can check the control board and the display. Find a mobile tech near you
From 16.2 Cu. Ft. 12V Built-In Vehicle Frost-Free Refrigerator-Freezer Troubleshooting and Service Manual (CCD-0007855) , Fault Display, Error Codes table.
The temperature sensor in the fridge part is not working.
When to call a tech Call a tech. The sensor needs a check. Find a mobile tech near you
From 16.2 Cu. Ft. 12V Built-In Vehicle Frost-Free Refrigerator-Freezer Troubleshooting and Service Manual (CCD-0007855) , Fault Display, Error Codes table.
The temperature sensor in the crisper drawer is not working.
When to call a tech Call a tech. The sensor needs a check. Find a mobile tech near you
From 16.2 Cu. Ft. 12V Built-In Vehicle Frost-Free Refrigerator-Freezer Troubleshooting and Service Manual (CCD-0007855) , Fault Display, Error Codes table.
The temperature sensor in the freezer is not working.
When to call a tech Call a tech. The sensor needs a check. Find a mobile tech near you
From 16.2 Cu. Ft. 12V Built-In Vehicle Frost-Free Refrigerator-Freezer Troubleshooting and Service Manual (CCD-0007855) , Fault Display, Error Codes table.
The sensor that controls defrost is not working.
When to call a tech Call a tech. The sensor needs a check. Find a mobile tech near you
From 16.2 Cu. Ft. 12V Built-In Vehicle Frost-Free Refrigerator-Freezer Troubleshooting and Service Manual (CCD-0007855) , Fault Display, Error Codes table.
A fan in the fridge is not working.
When to call a tech Call a tech. The fan needs a check. Find a mobile tech near you
From 16.2 Cu. Ft. 12V Built-In Vehicle Frost-Free Refrigerator-Freezer Troubleshooting and Service Manual (CCD-0007855) , Fault Display, Error Codes table.
The sensor that reads the air around the fridge is not working.
When to call a tech Call a tech. The sensor needs a check. Find a mobile tech near you
From 16.2 Cu. Ft. 12V Built-In Vehicle Frost-Free Refrigerator-Freezer Troubleshooting and Service Manual (CCD-0007855) , Fault Display, Error Codes table.
The fridge shut the compressor off because the battery power fell below 9 volts.
What you can check Check your 12-volt battery. Charge it or replace it if needed. When to call a tech If the battery is good and the code stays, call a tech. Find a mobile tech near you
From 16.2 Cu. Ft. 12V Built-In Vehicle Frost-Free Refrigerator-Freezer Troubleshooting and Service Manual (CCD-0007855) , Fault Display, Error Codes table.
The fridge shut the compressor off because the power was too high, above 11 volts after a battery change.
What you can check Wait 5 minutes and see if the code clears. When to call a tech If the code does not clear, call a tech. The charger or converter may be sending too much power. Find a mobile tech near you
From 16.2 Cu. Ft. 12V Built-In Vehicle Frost-Free Refrigerator-Freezer Troubleshooting and Service Manual (CCD-0007855) , Fault Display, Error Codes table.
Furrion tankless water heater Where the code shows: On the display of the control panel, such as E1; the heater shuts off when it finds an unsafe problem.
To reset: To reset after a lockout, turn the hot water faucet off and back on.
E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 En Fd
The sensor that reads the hot water leaving the heater is bad, or a wire came loose.
When to call a tech Call a tech. The sensor or its wires need a check. Find a mobile tech near you
From Furrion Tankless Water Heater Model F2GWH User Manual (CCD-0005833) , Troubleshooting.
The heater could not light, or the flame went out while it was lighting. After two tries it locks out.
If you smell propane, turn off the tank valve, get everyone out of your RV, and call for help from outside.
What you can check Make sure the propane tank has gas and the tank valve is open. To reset, turn the hot water faucet off and back on. When to call a tech If the code comes back, call a tech. The igniter, its wires, or the gas pressure may need service. Find a mobile tech near you
From Furrion Tankless Water Heater Model F2GWH User Manual (CCD-0005833) , Troubleshooting.
The flame went out while the heater was running. A buzzer sounds. The heater locks out.
If you smell propane, turn off the tank valve, get everyone out of your RV, and call for help from outside.
What you can check Make sure the propane tank has gas and the tank valve is open. To reset, turn the hot water faucet off and back on. When to call a tech If the code comes back, call a tech. The igniter or the gas supply may need service. Find a mobile tech near you
From Furrion Tankless Water Heater Model F2GWH User Manual (CCD-0005833) , Troubleshooting.
A safety switch (ECO) opened. This usually means the water at the outlet went over 140 degrees F.
When to call a tech Call a tech. The cause must be found and fixed before the heater runs again. Find a mobile tech near you
From Furrion Tankless Water Heater Model F2GWH User Manual (CCD-0005833) , Troubleshooting.
The sensor that reads the cold water coming in is bad, or a wire came loose.
When to call a tech Call a tech. The sensor or its wires need a check. Find a mobile tech near you
From Furrion Tankless Water Heater Model F2GWH User Manual (CCD-0005833) , Troubleshooting.
The heater did not get a signal from its blower motor. The motor or its wires may be bad.
When to call a tech Call a tech. The blower motor or its wires need a check. Find a mobile tech near you
From Furrion Tankless Water Heater Model F2GWH User Manual (CCD-0005833) , Troubleshooting.
The hot water was over 140 degrees F for 3 seconds.
When to call a tech Call a tech. The cause must be found before you use the heater again. Find a mobile tech near you
From Furrion Tankless Water Heater Model F2GWH User Manual (CCD-0005833) , Troubleshooting.
The heater found a break in the wiring to its gas valve (linear valve). The valve may be bad.
When to call a tech Call a tech. The valve needs to be checked or replaced. Find a mobile tech near you
From Furrion Tankless Water Heater Model F2GWH User Manual (CCD-0005833) , Troubleshooting.
The air switch did not sense air flow. The blower may be bad, or the air intake or exhaust may be blocked.
What you can check With the heater off, look at the outside air vents and the exhaust. Clear leaves, mud, and bug nests. When to call a tech If the vents are clear and the code stays, call a tech. The blower or the switch may need service. Find a mobile tech near you
From Furrion Tankless Water Heater Model F2GWH User Manual (CCD-0005833) , Troubleshooting.
The heater saw a flame before it lit. A buzzer sounds. The flame sensor may be shorted.
If you smell propane, turn off the tank valve, get everyone out of your RV, and call for help from outside.
When to call a tech Call a tech. The flame sensor needs a check. Find a mobile tech near you
From Furrion Tankless Water Heater Model F2GWH User Manual (CCD-0005833) , Troubleshooting.
The heater ran for more than 20 minutes.
What you can check Turn the hot water faucet off, then back on. When to call a tech If the code keeps coming back, call a tech. The control may need service. Find a mobile tech near you
From Furrion Tankless Water Heater Model F2GWH User Manual (CCD-0005833) , Troubleshooting.
This is not a fault. The heater is in Winter Use Mode and runs a few seconds to protect itself from freezing.
When to call a tech This mode only protects the heater, not your RV's water lines. If your plumbing is at risk of freezing, call a tech for help. Find a mobile tech near you